AC/DC Medical Power Module ADM360K120S001A

Features:

● Lata initus intentione: initus laboris intentione range est 100-240VAC

Minimum potentia consummatio: Non-onus <0.075W

● Maximum firmitatem: Obsequio cum EN60601-1 ORDO gradu salutis et 2×MOPP gradu tutelae velit, ac transitum CE

● Flamma retardat velit: UL94V-0 flamma retardat calor materia resistens

● Typi Praesidium: tutela brevis circuitus, super current protectio, super intentione praesidium, et sui ipsius recuperatio

 

 

 


Specification

Product Tags

Specification

03
Input laoreet condimentum
Voltage Range 100~240 VAC
Frequentia Range 50~60Hz
Input Current (Max.) 0.7A @ 115VAC,0.5A @ 230VAC
Efficientia (Typ.) 89%
Sto Consumptio 0.093W
Impetus Current (Typ.) 10A @115VAC,23A@230VAC
Lacus Current (Typ.) 0.1mA @ 264VAC, 60Hz

Output Parameters
Output intentione 12VDC
Tolerantia intentione ±5%
Output Current 3000mA
Rated Power (Max.) 36W
Linea ordinationis ± 0.5% ad plenam onus
Maximilianus.Capax Load 5000uF
Onus Ordinatione ±1%
Ripple & Noise 50mV (Typ.), 100mV (Max.)@20MHz
Frequentia (Typ.) 65kHz
Sustenta tempus (Typ.) 15mS @ 115VAC80mS @230VAC

Environment
Operating Temperature -40 ~ +70℃
Repono Temperature -40 ~ +85℃
Repono Umor (Max.) 95%RH (Max.)
Potestas Derating 2.7%/℃ @ -40 ~ -25℃

2.4%/℃ @ +50~ +70℃,12VDC

2.7%/℃ @ +55 ~ +70℃

Temperature Coefficient ±0.02%/℃
Solding Temperature 260±5℃@undam solidationem, 5~10s

360±10℃ @ Manuale Soldans, 3-5s

Praesidium Function
Brevis circuitus Longus terminus brevis circuitus, recuperatio auto-.
Plus Current ≥130% IO Auto recuperatio
Plus intentione ≤27VDC @ 12V output, ≤40VDC @ 24V output
IEC Safety Classis CLASSII'
Concursores electrica Concursores 2×MOPP @ primarius ad secundarium
Reliability
MTBF ≥300000H @ 25℃
Salus Signa / Directives
Medical salus EN60601-1
CE Obsequens
Solitudo Voltage (Min.) Initus ad output 4000VAC @1 minutus probatus et lacus vena minor quam 5mA.
EMC
 

 

 

Tactus

 

 

 

 

Parameter Standard Test Level / Note
Conducted emissionem EN55011(CISPR11)/EN55032(CISPR32) ORDO B
Emissio radiata EN55011(CISPR11)/EN55032(CISPR32) ORDO B
Voltage flammis EN61000-3-2 -
Harmonic current EN61000-3-2 -
EMS'

 

 

 

 

 

 

Parameter Standard Test Level / Note
Electrostatic Discharge IEC/EN61000-4-2 ±8KV/Contactus

±2、4、8、15KV/Aer

Radiate Susceptibilitas IEC/EN61000-4-3 10V/m
Electrical Fast Transiens ruptis IEC/EN61000-4-4 ±2 KV
Surge IEC/EN61000-4-5 ±0.5/±1 KV

Professional / Familia medicina

Conducted Susceptibilitas IEC/EN61000-4-6 3Vm/0.15MHz-80MHz 6Vm

(Within15m cohortis)

0.15MHz-80MHz

80%AM,1kHz

Voltage Dips et Interruptionem IEC/EN61000-4-11 0%UT 0.5cycle

0°,45°,90°,135°,180°,270°,315°。

0% UT 1cycle

70% UT 25/30 exolvuntur 0°

0%UT 250/300 cycle

 

 

Mechanica Specification
Dimension 65.79*44.54* 31.49mm
Claude Material Nigra flamma retardat et calor resistens materia plastica(UL94V-0)
Refrigerationem modus Naturalis aeris refrigerationem
Applicationem

1


  • Previous:
  • Deinde:

  •  

     

     

    Related Products